A copper wire coil changing from frosty cold to glowing hot, showing how resistance changes with temperature.

Electromagnetism

How Does Resistance Change With Temperature?

Have you ever noticed that a light bulb behaves differently the moment it is switched on, or that an electric motor feels warm after it has been running for a while? One reason is that the electrical resistance of the wires inside does not stay fixed. So, how does resistance change with temperature? In short, heating a metal wire usually makes its resistance increase, while heating a semiconductor usually makes its resistance decrease. This article explains why that happens, introduces the one formula that predicts the change for most everyday problems, and works through two complete numerical examples so that you can use the formula with confidence.

Before we go further, let us define the key term. Electrical resistance, measured in ohms (Ω), is a measure of how much a material opposes the flow of electric current. A high resistance means that, for a given voltage, less current flows. A low resistance means that current flows more easily. Resistance depends on the material, the length and thickness of the conductor, and, as this article shows, its temperature.

Temperature, in this context, is a measure of how vigorously the particles in a material are moving. When a solid is heated, its atoms vibrate more energetically about their fixed positions. Those vibrations turn out to be the main reason why the resistance of a metal changes. In a semiconductor, heating has a second, competing effect that wins out, and that is why its resistance moves in the opposite direction.

How Does Resistance Change With Temperature? The Short Answer

For a metal, the answer is simple: as temperature rises, resistance rises. As temperature falls, resistance falls. The change is roughly proportional to the temperature change, at least over the modest temperature ranges met in school and college problems. This behaviour is described by a positive temperature coefficient of resistance, a term we will define carefully in the next section.

For a semiconductor, such as silicon or germanium, and for an insulator such as carbon, the answer is the opposite: as temperature rises, resistance falls. This happens because heating releases more charge carriers, which are the charged particles that carry current, and the extra carriers more than make up for the extra scattering. The temperature coefficient is therefore negative for these materials.

For a few specially designed alloys, such as manganin and constantan, the resistance hardly changes at all with temperature. Their temperature coefficient is very close to zero. That property makes them ideal for standard resistors and measuring instruments, where a stable resistance is more important than a low resistance.

What Happens to Resistance When Temperature Rises?

To understand the metal case, we need a simple picture of current in a metal. A metal contains a lattice, which is a regular arrangement of positively charged metal ions held in fixed positions, and a sea of free electrons, which are electrons that are not bound to any one atom and can move through the lattice. When a voltage is applied, these free electrons drift through the metal, and that drift is the electric current.

As the electrons drift, they do not travel in smooth, uninterrupted paths. They collide with the vibrating ions of the lattice and with imperfections in the crystal. Each collision is called scattering, because it deflects the electron from its path and slows its forward drift. The more often scattering happens, the harder it is for current to flow, and the higher the resistance.

Now consider what heating does. At a higher temperature, the ions vibrate with larger amplitude, meaning they swing further from their average positions. They present a bigger, more disturbed target to the passing electrons. The electrons are therefore scattered more often, their drift is impeded more strongly, and the resistance of the metal increases. Cooling has the reverse effect: the ions vibrate less, scattering decreases, and resistance falls.

This picture also explains why the resistance of a metal does not fall to zero at everyday low temperatures. Even at low temperatures, electrons are still scattered by impurities and by imperfections in the lattice, so some resistance remains. Only in superconductors, a special class of materials cooled below a critical temperature, does resistance vanish completely, and that is a separate phenomenon beyond the scope of this article.

Semiconductors behave differently because their supply of charge carriers is not fixed. At low temperatures, most electrons in a semiconductor are bound to their atoms, and few are free to carry current. Heating gives some electrons enough energy to break free, creating both free electrons and positively charged holes, which are empty electron states that behave like positive charge carriers. The number of carriers rises rapidly with temperature, and because there are far more carriers available, the current flows more easily even though scattering also increases. The net result is that resistance falls as temperature rises.

The quantitative law that captures the metal case, and the linear approximation often used for other materials over a small range, is:

R = R₀(1 + αΔT)

Here, R is the resistance at the new temperature, measured in ohms. R₀ is the resistance at a reference temperature, also in ohms, usually 0 °C or 20 °C. The symbol α, the Greek letter alpha, is the temperature coefficient of resistance, which we define in the next section. The symbol ΔT, read as delta T, is the change in temperature, equal to the new temperature minus the reference temperature. It is measured in degrees Celsius (°C) or kelvin (K), and because it is a change rather than an absolute temperature, a change of 1 °C is exactly equal to a change of 1 K.

Notice what the formula says in words. The resistance at the new temperature equals the reference resistance multiplied by one plus a small correction. That correction is the product of α and the temperature change. If the temperature rises, ΔT is positive, and for a metal with positive α, the resistance grows. If the temperature falls, ΔT is negative, and the resistance shrinks. For a material with negative α, the opposite happens, exactly as observed for semiconductors.

The Temperature Coefficient of Resistance (α)

The temperature coefficient of resistance, written as α, is defined as the fractional change in resistance per degree change in temperature. In plain language, it tells you what fraction of the original resistance is gained or lost for each degree of heating or cooling. A material with a large α changes its resistance quickly with temperature. A material with a small α changes slowly.

The definition can be written as a formula:

α = ΔR / (R₀ΔT)

In this formula, ΔR is the change in resistance, equal to the new resistance minus the reference resistance, measured in ohms. R₀ is the resistance at the reference temperature, in ohms. ΔT is the change in temperature, in degrees Celsius or kelvin. Dividing a fractional change by a temperature change gives α the unit of per degree Celsius (per °C) or per kelvin (per K). The two units are numerically equal for this purpose, because a one-degree change is the same size on both scales.

Because α is defined at a stated reference temperature, its value depends on which reference temperature is chosen. A value quoted at 20 °C is not exactly the same as a value quoted at 0 °C, although the difference is small for most problems. For this reason, good tables and problem statements always state the reference temperature, and you should always check which reference your value of α belongs to before using it.

Rearranging the definition gives a second useful form of the resistance-temperature law, called the reference-temperature form:

R = R₀[1 + α(T − T₀)]

Here, T is the new temperature and T₀ is the reference temperature. The bracket (T − T₀) is simply ΔT written out in full. This form is especially helpful when the reference temperature is 20 °C, which is a common laboratory temperature, because it reminds you to subtract 20 °C rather than treating the new temperature itself as the change.

The sign of α carries the physics. A positive α means resistance increases with temperature, which is the behaviour of pure metals. A negative α means resistance decreases with temperature, which is the behaviour of semiconductors and insulators such as carbon. A near-zero α means resistance is almost independent of temperature, which is the behaviour of precision alloys. The table below gives approximate α values at 20 °C for some common materials. These are typical textbook values; exact values vary slightly with purity and composition.

MaterialTemperature coefficient α at 20 °C (per °C)Behaviour on heating
Copper0.00393Resistance increases
Aluminium0.0039Resistance increases
Iron0.0050Resistance increases
Nichrome0.0004Resistance increases slightly
Carbon−0.0005Resistance decreases

Read the copper row as an example. An α of 0.00393 per °C means that, for each degree Celsius of heating, the resistance of copper increases by about 0.393 percent of its value at the reference temperature. Over a 100 °C rise, that adds up to roughly a 39 percent increase, which is far from negligible in a motor winding or a long power cable. Nichrome, by contrast, has a very small α, which is one reason it is used for heating elements: its resistance, and therefore its heating power, stays fairly steady as it gets hot.

It is also worth noting what the linear formula does not do. It is an approximation that works well over moderate temperature ranges, typically a few tens or a few hundreds of degrees. Over very large ranges, α itself changes with temperature, and the true relationship between resistance and temperature becomes curved rather than straight. For the problems in this article, and for most examination questions, the linear formula is the intended tool.

There is one more related quantity worth knowing. Resistivity, written as ρ and measured in ohm-metres, is a property of the material itself, independent of the size or shape of a particular sample, whereas resistance depends on both the material and the geometry. Resistivity follows the same kind of temperature law, ρ = ρ₀(1 + αΔT), with the same α. This is why you will sometimes see the temperature discussion framed in terms of resistivity rather than resistance; the physics and the coefficient are the same.

Worked Example 1 — Copper Coil Heated from 20 °C to 80 °C

A copper coil has a resistance of 10 Ω at 20 °C. The temperature coefficient of resistance of copper is 0.00393 per °C. Find the resistance of the coil when it is heated to 80 °C.

Step 1: List what is given. The reference resistance R₀ is 10 Ω, and the reference temperature T₀ is 20 °C. The new temperature T is 80 °C. The temperature coefficient α is 0.00393 per °C.

Step 2: Find the temperature change. The change ΔT is the new temperature minus the reference temperature, so ΔT = 80 °C − 20 °C = 60 °C. Note that we subtract; we do not simply insert 80 °C into the formula.

Step 3: Write the formula. We use R = R₀(1 + αΔT), because R₀ is given at the reference temperature and ΔT is now known.

Step 4: Substitute the numbers. R = 10 Ω × (1 + 0.00393 per °C × 60 °C). The units of per °C and °C cancel in the product, leaving a pure number, as they must inside the bracket.

Step 5: Evaluate the bracket. First, 0.00393 × 60 = 0.2358. Then, 1 + 0.2358 = 1.2358. This tells us the resistance grows by about 23.58 percent.

Step 6: Multiply and state the answer. R = 10 Ω × 1.2358 = 12.358 Ω, which rounds to 12.36 Ω. The resistance of the copper coil at 80 °C is therefore approximately 12.36 Ω, an increase of about 2.36 Ω over its value at 20 °C.

As a sense check, the answer is larger than 10 Ω, as expected for a heated metal, and the increase is roughly a quarter of the original value, which matches an α of about 0.004 per °C multiplied by a 60 °C rise. If your answer had come out smaller than 10 Ω, that would be a sign that a sign or subtraction had gone wrong.

Worked Example 2 — Finding α from Two Measurements

A wire measures 5 Ω at 50 °C and 6 Ω at 100 °C. Find the temperature coefficient of resistance α of the wire, and find its resistance R₀ at 0 °C.

Step 1: Understand the unknowns. We have two measurements but neither R₀, the resistance at the reference temperature of 0 °C, nor α is given. We therefore need two equations, one for each measurement, and we will solve them together.

Step 2: Write the two equations. Using R = R₀(1 + αT) with the reference temperature taken as 0 °C, so that the temperature change from the reference is simply the Celsius temperature itself, the first measurement gives 5 Ω = R₀(1 + α × 50 °C), and the second gives 6 Ω = R₀(1 + α × 100 °C). To keep the algebra clean, we can drop the units inside the brackets and restore them at the end, remembering that α is in per °C.

Step 3: Eliminate R₀ by dividing. Divide the second equation by the first, so that R₀ cancels: 6 Ω / 5 Ω = (1 + 100α) / (1 + 50α). The left-hand side is 1.2, a pure number, so we have 1.2 = (1 + 100α) / (1 + 50α).

Step 4: Cross-multiply and solve for α. Multiply both sides by (1 + 50α) to get 1.2 × (1 + 50α) = 1 + 100α. Expanding the left-hand side gives 1.2 + 60α = 1 + 100α. It is cleaner to work with the unrounded fractions: 6 × (1 + 50α) = 5 × (1 + 100α), which expands to 6 + 300α = 5 + 500α. Subtracting 5 from both sides and 300α from both sides gives 1 = 200α, so α = 1 / 200 = 0.005 per °C.

Step 5: Back-substitute to find R₀. Insert α = 0.005 per °C into the first equation: 5 Ω = R₀(1 + 0.005 × 50) = R₀(1 + 0.25) = R₀ × 1.25. Dividing both sides by 1.25 gives R₀ = 5 Ω / 1.25 = 4 Ω.

Step 6: Check the answer. Using R₀ = 4 Ω and α = 0.005 per °C, the resistance at 100 °C should be 4 Ω × (1 + 0.005 × 100) = 4 Ω × 1.5 = 6 Ω, which matches the second measurement exactly. The temperature coefficient of the wire is therefore 0.005 per °C, and its resistance at 0 °C is 4 Ω.

This second example illustrates a general examination technique. Whenever you are given two resistance-temperature pairs and neither R₀ nor α, set up two equations, eliminate the unknown you do not need by dividing, solve for α, and then substitute back for R₀. The method works because the unknown R₀ is a common factor in both equations.

Common Mistakes

Using the Celsius temperature directly instead of the temperature change ΔT. The formula needs the change from the reference temperature, not the temperature itself. If R₀ is given at 20 °C and the new temperature is 80 °C, ΔT is 60 °C, not 80 °C. Forgetting the subtraction is the single most common error in this topic.

Mixing up R₀ with the resistance at 0 °C when the reference is 20 °C. R₀ means the resistance at whatever reference temperature your value of α belongs to. If α is quoted at 20 °C, then R₀ is the resistance at 20 °C. Treating that value as if it were the resistance at 0 °C shifts every later answer.

Assuming α stays constant over very large temperature ranges. The linear formula R = R₀(1 + αΔT) is an approximation. Over a range of hundreds of degrees, the true resistance-temperature curve bends, α drifts, and the linear prediction becomes unreliable. For very large ranges, a quadratic or tabulated relationship is needed.

Applying a metal’s positive α to a semiconductor. The sign matters. A semiconductor has a negative temperature coefficient, so its resistance falls when heated. Using a positive α for a semiconductor, or a negative α for a metal, reverses the predicted direction of change and guarantees a wrong answer.

Forgetting that α itself is defined at a stated reference temperature. An α quoted at 0 °C and an α quoted at 20 °C are slightly different numbers for the same material. Always pair a value of α with its reference temperature, and make sure R₀ is the resistance at that same temperature.

Two smaller slips are also worth avoiding. First, keep the units consistent: α is per degree, so ΔT must be in degrees, and the product αΔT must be dimensionless before you add one to it. Second, do not confuse resistance with resistivity. They share the same α and the same form of formula, but resistance depends on the shape of the sample while resistivity does not, so the two quantities cannot be interchanged in a numerical answer.

Conclusion

To sum up, how does resistance change with temperature? For metals, resistance increases as temperature increases, because hotter lattice ions vibrate more vigorously and scatter the free electrons more often. For semiconductors and insulators, resistance decreases as temperature increases, because heating frees many more charge carriers and that effect outweighs the extra scattering. For precision alloys such as manganin and constantan, resistance barely changes at all.

The key formulas to remember are R = R₀(1 + αΔT), which predicts the resistance at a new temperature; α = ΔR / (R₀ΔT), which defines the temperature coefficient of resistance as the fractional change per degree; and the reference-temperature form R = R₀[1 + α(T − T₀)], which makes the choice of reference temperature explicit. Metals have a positive α, semiconductors have a negative α, and precision alloys have a near-zero α. Keep ΔT as a genuine temperature change, pair every α with its reference temperature, and remember that the linear law is an approximation that works best over moderate ranges. With those habits, resistance-temperature problems become straightforward applications of one formula, carefully applied.

Frequently Asked Questions

Does the resistance of a metal increase or decrease with temperature?

The resistance of a metal increases as its temperature rises. Heating makes the lattice ions vibrate with larger amplitude, so they scatter the drifting free electrons more often, impeding current flow. Cooling reverses the effect: the ions vibrate less, scattering decreases, and resistance falls. This behaviour is described by a positive temperature coefficient of resistance, α.

What is the temperature coefficient of resistance, and what does α tell us about a material?

The temperature coefficient of resistance, α, is the fractional change in resistance per degree change in temperature. It tells you what fraction of the reference resistance is gained or lost for each degree of heating or cooling, defined by α = ΔR / (R₀ΔT). A large α means resistance changes quickly with temperature, a small α means it changes slowly, and its sign shows whether resistance rises or falls.

How do you use the formula R = R₀(1 + αΔT) to find resistance at a new temperature?

You use R = R₀(1 + αΔT) by first finding ΔT, the new temperature minus the reference temperature, then multiplying α by ΔT, adding one, and multiplying by R₀. For example, a copper coil of 10 Ω at 20 °C heated to 80 °C has ΔT = 60 °C, so R = 10 Ω × (1 + 0.00393 × 60) = 12.36 Ω. Remember to subtract the reference temperature rather than inserting the new temperature directly.

Why does the resistance of a semiconductor decrease when temperature increases, while a metal’s resistance increases?

A semiconductor’s resistance decreases with heating because heating frees many more charge carriers, and that effect outweighs the extra scattering. At low temperatures most electrons are bound to their atoms, but heating releases free electrons and holes, so far more carriers are available to carry current. In a metal, by contrast, the carrier supply is already fixed, so increased lattice vibration and scattering dominate and resistance rises.

What is the temperature coefficient of resistance of copper, and how much does copper’s resistance change per degree?

The temperature coefficient of resistance of copper is 0.00393 per °C at 20 °C. This means copper’s resistance increases by about 0.393 percent of its reference resistance for each degree Celsius of heating. Over a 100 °C rise, that adds up to roughly a 39 percent increase, which is far from negligible in a motor winding or a long power cable. Pair this α value with its 20 °C reference temperature when using it.

Is the temperature coefficient of resistance the same at every temperature, or does the linear resistance-temperature formula break down?

No, α is not the same at every temperature, and the linear formula R = R₀(1 + αΔT) is only an approximation. It works well over moderate ranges of a few tens or hundreds of degrees, but over very large ranges α itself drifts with temperature and the true resistance-temperature curve bends. For very large ranges, a quadratic or tabulated relationship is needed instead, and every α value must be paired with its stated reference temperature.

Similar Posts