what is a transformer step up step down and the turns ratio

Electromagnetism

What Is a Transformer? Step-Up, Step-Down and the Turns Ratio Explained

Plug a phone charger into the wall and 230 V of mains electricity goes in one end. Safe low voltage power comes out the other end, ready to charge a battery. The small box doing that job is a transformer. So what is a transformer, exactly? It is a device that changes alternating current voltage from one level to another, using electromagnetic induction. It has no moving parts, no battery and no plug of its own. It takes the voltage it is given and hands back a different voltage, and one simple ratio decides how big that change is.

This article explains that ratio, shows how to tell a step-up transformer from a step-down one, and works through two full numerical examples. By the end you will be able to calculate secondary voltage from turns and primary voltage, and to work out efficiency when a real transformer loses some energy as heat.

What Is a Transformer?

A transformer is an electrical device that changes AC voltage from one level to another by electromagnetic induction. The words in that sentence each matter. AC means alternating current, the kind of current that flows back and forth and keeps changing direction. Electromagnetic induction is the process where a changing magnetic field creates, or induces, a voltage in a wire. A transformer uses that effect to pass energy from one coil of wire to another without the two coils ever touching electrically.

Inside a transformer sit two coils of wire wound around a shared iron core. The coil connected to the power supply is called the primary coil. The coil connected to the load, the thing that needs power, is called the secondary coil. The core is usually made of iron, and it is built up from thin sheets called laminations rather than one solid block. Those sheets matter, and the reason for them appears later in this article.

There is no wire joining the primary coil to the secondary coil. The link between them is purely magnetic. Energy crosses from one coil to the other through the magnetic field in the core. That separation is one reason transformers show up in so many places. A phone charger can keep the dangerous mains side away from the low voltage side that touches your phone, because the two sides share a magnetic field and nothing else.

Faraday’s law sits at the heart of the whole device. It says that a changing magnetic flux through a coil induces an electromotive force, or EMF, in that coil. Magnetic flux is a measure of how much magnetic field passes through an area, and EMF is the voltage a changing flux creates. In a transformer, the alternating current in the primary coil creates a magnetic flux that keeps changing. That changing flux threads through the secondary coil, and Faraday’s law does the rest: a voltage appears across the secondary coil.

A transformer cannot work with DC. Direct current flows in one direction only and stays steady. A steady current creates a steady magnetic field, and a steady field creates no changing flux. With no changing flux, Faraday’s law gives no induced EMF in the secondary coil, so nothing comes out. Connect a transformer to a DC supply and the secondary stays dead, while the primary coil can overheat because its resistance is the only thing limiting the current. This is the first fact to fix in your head: transformers need changing current, which in practice means alternating current.

How a Transformer Works, Step by Step

The process runs through four stages, and each one follows from the last. Once you see the chain, the formula in the next section stops looking like a rule to memorise and starts looking like common sense.

First, alternating current flows through the primary coil. The current rises, falls, reverses and rises again, many times each second. Mains electricity in most countries alternates 50 times per second. Because the current keeps changing, the magnetic field it creates around the primary coil keeps changing too.

Second, the iron core guides that changing magnetic field. Iron is a good magnetic material, so the field prefers to travel through the core rather than leak away into the air around it. The core forms a closed loop, and almost all the magnetic flux the primary coil creates is channelled through the secondary coil as well.

A core made of solid iron would work as a guide, but it would also let large wasteful currents swirl inside the iron itself. That is why the core is laminated. Thin sheets of iron, each insulated from the next, break up those swirling currents, called eddy currents, and keep the energy loss small.

Third, the changing flux passes through the secondary coil and induces an EMF there. Faraday’s law says the induced EMF in a coil equals the number of turns in the coil multiplied by the rate of change of flux through it. The flux changes at the same rate in both coils because both sit on the same core, so the only difference between the two coils is how many turns of wire each one has.

Fourth, that shared rate of change gives both coils the same volts per turn. If each turn of the primary coil gets, say, 0.5 V induced in it, then each turn of the secondary coil also gets 0.5 V. A coil with 100 turns then has 50 V across it, and a coil with 400 turns has 200 V across it. Count the turns and you know the voltage. That single observation is the whole basis of the turns ratio.

The Turns Ratio Formula

The turns ratio is the relationship between the number of turns on each coil and the voltages across them. Because both coils share the same volts per turn, the ratio of the voltages equals the ratio of the turns. Written as a formula, it looks like this:

Np / Ns = Vp / Vs = Is / Ip

Every symbol in that line needs a plain definition before you use it. Np is the number of turns on the primary coil. Ns is the number of turns on the secondary coil. Vp is the voltage across the primary coil. Vs is the voltage across the secondary coil. Ip is the current in the primary coil. Is is the current in the secondary coil. Turns are pure counts, so Np and Ns have no unit. Voltages should be RMS values, which are the effective values of alternating voltage that mains supplies and meters report.

That one line hides three useful rearrangements, and exam questions use all of them. To find the secondary voltage, use Vs = Vp × Ns / Np. To find how many secondary turns you need, use Ns = Np × Vs / Vp. To find the primary voltage from the secondary side, use Vp = Vs × Np / Ns. The pattern to remember is that the two quantities on the same side of the transformer stay together: primary turns with primary voltage, secondary turns with secondary voltage.

A quick check shows how the formula behaves. Take a primary coil with 100 turns and a secondary coil with 200 turns, and connect 10 V AC to the primary. The secondary has twice as many turns, so it gets twice the voltage: Vs = 10 × 200 / 100 = 20 V. Swap the coils round, with 200 turns on the primary and 100 on the secondary, and the same 10 V supply gives Vs = 10 × 100 / 200 = 5 V. More turns on the secondary means more voltage out. Fewer turns means less.

The third part of the formula, Is / Ip, tells you what happens to current. In an ideal transformer, the current ratio is the inverse of the turns ratio. That means current does the opposite of voltage. When voltage steps up, current steps down by the same factor, and when voltage steps down, current steps up. The next two sections use that fact heavily, because it is where most exam marks are lost.

Step-Up Transformer vs Step-Down Transformer

Step-up and step-down are just two directions of the same device. Which one you have depends only on which coil has more turns.

Step-Up Transformer

A step-up transformer has more turns on the secondary coil than on the primary coil, so Ns is greater than Np and Vs is greater than Vp. The turns ratio Np / Ns is less than 1. Voltage goes up and, because energy is conserved, current goes down. Power stations use step-up transformers to raise the voltage of the electricity they generate before it travels across the country. High voltage cuts the current, and low current cuts the wasted energy, which the efficiency section covers below.

Step-Down Transformer

A step-down transformer has fewer turns on the secondary coil than on the primary coil, so Ns is less than Np and Vs is less than Vp. The turns ratio Np / Ns is greater than 1. Voltage goes down and current goes up. Phone chargers are step-down transformers. So are the transformers inside doorbells, and the distribution transformers mounted on poles or in green boxes near homes, which bring the high voltage of the transmission network down to the 230 V that sockets supply.

The 1:1 Isolation Transformer

One special case deserves a mention. When the primary and secondary coils have the same number of turns, Ns equals Np and the voltage comes out the same as it went in. The transformer then does not change the voltage at all. Its job is isolation: it keeps the two circuits electrically separate while still passing power between them through the magnetic field. Workshops and hospitals use isolation transformers where that separation is a safety feature.

A table makes the comparison easy to hold in your head.

TypeTurnsVoltageCurrentTurns ratio Np / Ns
Step-upNs > NpVs > VpIs < IpLess than 1
Step-downNs < NpVs < VpIs > IpGreater than 1
Isolation (1:1)Ns = NpVs = VpIs = IpEqual to 1

Notice the pattern in the table. Voltage and current always move in opposite directions. That pattern follows from the conservation of energy, and the next section shows why.

Power Conservation and Efficiency

An ideal transformer loses no energy at all. Every watt that goes in comes out the other side, so power in equals power out. Electrical power equals voltage multiplied by current, so the ideal transformer obeys a simple equation:

Vp × Ip = Vs × Is

That equation explains the current behaviour from the last section. If the secondary voltage is twice the primary voltage, the secondary current must be half the primary current, or the two sides would not balance. A step-up transformer trades current for voltage. A step-down transformer trades voltage for current. Neither one creates energy. The power out can never exceed the power in, and in a perfect transformer the two are exactly equal.

Real transformers are not ideal. Some energy always escapes as heat, and it escapes through two main routes. Copper loss is the heating of the copper wire in the coils. Current flowing through any wire warms it, and the windings of a transformer are no exception. The loss grows with the square of the current, so doubling the current quadruples the copper loss.

Core loss is the energy wasted inside the iron core itself, mainly through eddy currents swirling in the iron and through hysteresis, the energy spent magnetising and demagnetising the core 50 times a second. Laminating the core cuts the eddy current part of this loss, but it never reaches zero.

Efficiency measures how much of the input power survives as useful output power. It is given as a percentage:

Efficiency = (power out / power in) × 100% = (Vs × Is) / (Vp × Ip) × 100%

A transformer rated at 90% efficiency turns 90 W out of every 100 W in into useful power, and the other 10 W becomes heat. Large power transformers in the grid run at efficiencies above 95%, and the best ones approach 99%. Small chargers and adapters are less efficient, which is why a phone charger feels warm after an hour of use. That warmth is the lost energy leaving as heat.

Efficiency also explains why the grid steps voltage up for long distance transmission. The power lost as heat in a transmission cable equals I squared × R, where I is the current and R is the resistance of the cable.

For a fixed amount of power, raising the voltage lowers the current in the same proportion. Double the voltage and the current halves. Because the loss depends on the square of the current, halving the current cuts the loss to a quarter. Raise the voltage ten times and the current falls to a tenth, so the loss falls to a hundredth.

That is why power stations step voltage up to hundreds of thousands of volts to carry power across the country, and why distribution transformers step it back down near homes where such high voltage would be dangerous.

Worked Example 1: Step-Down Transformer

A transformer has 1000 turns on its primary coil and 50 turns on its secondary coil. The primary coil is connected to a 240 V AC supply. Find the secondary voltage, state whether the transformer is step-up or step-down, and find the secondary current if the primary current is 0.1 A. Assume the transformer is ideal.

Step 1: List what you know. Np = 1000 turns, Ns = 50 turns, Vp = 240 V, Ip = 0.1 A. You need Vs and Is.

Step 2: Find the secondary voltage with the turns ratio rearranged for Vs. Vs = Vp × Ns / Np = 240 × 50 / 1000. The fraction 50 / 1000 is 0.05, so Vs = 240 × 0.05 = 12 V. The secondary voltage is 12 V.

Step 3: Decide the type. The secondary coil has 50 turns and the primary has 1000, so Ns is less than Np. The voltage has fallen from 240 V to 12 V, which confirms it. This is a step-down transformer.

Step 4: Find the secondary current. For an ideal transformer, Is / Ip = Np / Ns, so Is = Ip × Np / Ns = 0.1 × 1000 / 50. The fraction 1000 / 50 is 20, so Is = 0.1 × 20 = 2 A. The secondary current is 2 A.

Step 5: Check the answer with power. Power in = Vp × Ip = 240 × 0.1 = 24 W. Power out = Vs × Is = 12 × 2 = 24 W. The two match, which is exactly what an ideal transformer should give. If they did not match, something in the arithmetic went wrong. That quick power check catches most slips.

Worked Example 2: Step-Up Transformer with Efficiency

A transformer has 200 turns on its primary coil and 1000 turns on its secondary coil. The primary coil is connected to a 120 V AC supply and draws a current of 2.5 A. Find the secondary voltage, then find the efficiency of the transformer if the secondary coil delivers a current of 0.45 A.

Step 1: List what you know. Np = 200 turns, Ns = 1000 turns, Vp = 120 V, Ip = 2.5 A, Is = 0.45 A. You need Vs and the efficiency.

Step 2: Find the secondary voltage. Vs = Vp × Ns / Np = 120 × 1000 / 200. The fraction 1000 / 200 is 5, so Vs = 120 × 5 = 600 V. The secondary voltage is 600 V.

Step 3: Decide the type. The secondary coil has 1000 turns against 200 on the primary, so Ns is greater than Np, and the voltage has risen from 120 V to 600 V. This is a step-up transformer.

Step 4: Work out the power in. Power in = Vp × Ip = 120 × 2.5 = 300 W.

Step 5: Work out the power out. Power out = Vs × Is = 600 × 0.45 = 270 W. The output is 30 W short of the input, and that 30 W is the energy lost as heat in the windings and the core.

Step 6: Find the efficiency. Efficiency = (power out / power in) × 100% = (270 / 300) × 100% = 0.9 × 100% = 90%. The transformer is 90% efficient.

Step 7: Sanity check the current. In an ideal transformer, the secondary current would have been Is = Ip × Np / Ns = 2.5 × 200 / 1000 = 0.5 A. The real secondary current is 0.45 A, which is lower, as it should be when energy is lost. If the real current had come out higher than the ideal value, that would be a sign of a mistake, because a real transformer can never deliver more than the ideal case.

Common Mistakes to Avoid

  • Inverting the turns ratio is the most frequent error. When solving for Vs, the fraction must be Ns / Np, with secondary turns on top. Putting Np on top gives the reciprocal of the right answer, and the power check in the worked examples will expose it at once.
  • Thinking a transformer works with DC. A steady current makes a steady magnetic field, and a steady field induces nothing in the secondary coil. A transformer needs alternating current, or at least a current that keeps changing.
  • Thinking a step-up transformer creates extra power. It does not. Voltage rises, so current must fall by the same factor, and the power stays the same in the ideal case. Free energy does not exist, and a transformer is not an exception.
  • Reading the ratio the wrong way round and calling a step-down transformer a step-up one. Check the turns first, before any calculation. If Ns is smaller than Np, the voltage falls, whatever the numbers seem to say.
  • Forgetting that real transformers are not 100% efficient. The turns ratio formula gives voltages correctly, but the current formula Is = Ip × Np / Ns only holds for an ideal transformer. In a real transformer the secondary current is lower, and the efficiency formula is the tool that measures by how much.
  • Mixing up primary and secondary when labelling Vp, Vs, Np and Ns. The primary is always the coil connected to the supply, and the secondary is always the coil connected to the load. Get that backwards and every formula gives the reciprocal of the right answer.

What a Transformer Really Comes Down To

Now you can answer the question this article opened with. What is a transformer? It is a device that changes AC voltage from one level to another through electromagnetic induction, using two coils on a shared iron core and no electrical connection between them.

The turns ratio controls everything it does: Np / Ns = Vp / Vs = Is / Ip. More turns on the secondary steps the voltage up and the current down. Fewer turns steps the voltage down and the current up.

An ideal transformer conserves power, Vp × Ip = Vs × Is, and a real one loses a little energy as heat, measured by efficiency = (Vs × Is) / (Vp × Ip) × 100%.

Keep those four formulas with you and most transformer problems reduce to spotting which symbols you know and rearranging for the one you need. Check the turns first to name the type, run the power check to catch an inverted ratio, and remember that a transformer trades voltage against current. It never creates power, and it never works with DC.

Frequently Asked Questions

Can a transformer work with DC, or does it only work with AC?

No, a transformer cannot work with DC and only works with AC. Direct current flows steadily in one direction, so it creates a steady magnetic field with no changing flux in the iron core. Faraday's law says only a changing flux induces an EMF in the secondary coil, so a DC supply produces no secondary voltage at all. The primary coil can also overheat because only its small resistance limits the current.

Why does a step up transformer increase voltage but decrease current?

A step up transformer increases voltage but decreases current because it conserves power. Ideally, power in equals power out, so Vp × Ip = Vs × Is. When the secondary coil has more turns than the primary, the turns ratio Np/Ns = Vp/Vs raises the secondary voltage. For the power on both sides to stay equal, the secondary current must fall by the same factor. Voltage and current always trade against each other.

How do I calculate the turns ratio of a transformer?

Calculate the turns ratio with Np/Ns = Vp/Vs = Is/Ip. Np and Ns are the turn counts on the primary and secondary coils, Vp and Vs are their voltages, and Ip and Is are their currents. Divide primary turns by secondary turns to get the ratio, or use the voltages instead. Rearrange for the missing value, for example Vs = Vp × Ns/Np. In an ideal transformer, Vp × Ip equals Vs × Is, so check the power balances.

What is the difference between a step up transformer and a step down transformer?

A step up transformer raises voltage while a step down transformer lowers it. In a step up transformer the secondary coil has more turns than the primary, so Ns is greater than Np, Vs is greater than Vp, and the turns ratio Np/Ns is less than 1. In a step down transformer Ns is less than Np, so Vs is less than Vp and Np/Ns is greater than 1. Current always moves the opposite way to voltage.

Why is a transformer not 100% efficient?

A transformer is not 100% efficient because some energy always escapes as heat. Copper loss heats the copper windings, since current flowing through any wire warms it, and the loss grows with the square of the current. Core loss wastes energy inside the iron core through eddy currents swirling in the iron and hysteresis. Efficiency = (Vs × Is)/(Vp × Ip) × 100% measures how much input power survives as useful output.

Can a transformer increase power, or does the turns ratio only change voltage and current?

No, a transformer cannot increase power; the turns ratio only changes voltage and current. In an ideal transformer power in equals power out, Vp × Ip = Vs × Is, so any rise in voltage is matched by an equal fall in current. A step up transformer trades current for voltage, and a step down transformer trades voltage for current. Real transformers deliver less power than ideal ones, because copper loss and core loss turn some energy into heat.