Heat Pumps and Refrigerators: How Cooling Cycles Work

Stand in front of an open fridge and you feel cold air on your face. Step behind it and the air feels warm. One machine does both things at once, and that looks like a trick. Heat is supposed to flow from hot things to cold things, never the other way round, so how does a fridge pull heat out of food that is already cold and dump it into a warmer kitchen?

The heat pump and refrigerator coefficient of performance, called COP, measures how much useful heat a machine moves for each unit of work it consumes, and it is the number that answers that puzzle.

A fridge and a heat pump are the same device with different goals. A fridge keeps a box cold by throwing heat out of it. A heat pump keeps a room warm by pulling heat in from the cold air outside. Both spend work to move heat uphill, from cold to hot, and both are judged by the same ratio.

This article walks through the cooling cycle step by step, defines COP for a refrigerator and for a heat pump, shows the link between the two, and sets the Carnot limit that no real machine can beat. Two worked examples finish the job, with every number shown.

A Heat Engine Running in Reverse

A heat engine takes heat from a hot source, turns part of it into work, and dumps the rest into a cold sink. A car engine does this. A power station does this. A refrigerator does the same process backwards.

It takes in work and uses it to push heat from a cold place to a hot place. That reversal is the whole idea behind cooling.

The second law of thermodynamics says heat never flows from a cold body to a hot body on its own. This is the Clausius statement of the second law. Left alone, heat flows downhill, from hot to cold, until temperatures even out.

A fridge breaks that pattern only because it pays for it with work. Plug it out and the inside warms up to room temperature within hours. The work input is what keeps the unnatural flow going.

Three quantities describe the cycle. QC is the heat removed from the cold reservoir, the inside of the fridge. QH is the heat delivered to the hot reservoir, the kitchen air. W is the work the compressor consumes over one cycle.

A reservoir is just a body large enough that its temperature barely changes while heat flows in or out of it. The fridge interior and the kitchen both count as reservoirs for this purpose.

Energy has to balance over one complete cycle. The refrigerant returns to its starting state at the end of each loop, so its internal energy is the same at the start and the end.

The first law of thermodynamics then gives a simple result: the heat delivered to the hot side equals the heat taken from the cold side plus the work put in. In symbols, QH = QC + W. Rearranged, the work input is W = QH − QC.

This one equation sits behind nearly every calculation in this topic. It also explains why the back of a fridge feels warm. The kitchen receives not only the heat pulled out of the food but also the electrical work the compressor consumed, converted to heat along the way.

Notice what this means for the two machines. A refrigerator and a heat pump run the identical cycle. The difference is only which end the owner cares about. The fridge owner wants QC, the heat removed from the cold box. The heat pump owner wants QH, the heat delivered to the warm room. Same hardware, same physics, different useful output.

That single fact explains why the two COP formulas look so similar, and why they differ by exactly one.

The Vapour-Compression Cooling Cycle, Step by Step

Real fridges and heat pumps use a cycle called the vapour-compression cycle. It runs on a refrigerant, a fluid chosen because it boils at a low temperature and absorbs a lot of heat when it evaporates. Old refrigerants included ammonia and chlorofluorocarbons. Modern domestic fridges mostly use hydrocarbons such as isobutane or hydrofluoroolefins, picked for low environmental harm.

The name of the fluid changes with the decade. The cycle stays the same.

The refrigerant travels in a closed loop through four parts, always in the same order. Each part changes the refrigerant in one specific way. Follow one parcel of refrigerant around the loop and the whole machine makes sense.

1. The compressor

The cycle starts at the compressor, the humming box at the back of a fridge. Low pressure vapour from the evaporator enters the compressor, and the compressor squeezes it. Squeezing a gas raises both its pressure and its temperature, so the refrigerant leaves as a hot, high pressure vapour.

This is the only step that consumes work. Everything else in the loop happens on its own once the compressor has done its job.

2. The condenser

The hot vapour flows into the condenser, the coil of thin tubing fixed to the back of the fridge or hidden underneath it. Kitchen air is cooler than the vapour, so heat flows out of the refrigerant and into the room. As it loses heat, the vapour condenses into a warm liquid.

The heat given out here is QH, the heat dumped into the hot reservoir. If you touch the back of a running fridge, the warmth you feel is the condenser doing its work.

3. The expansion valve

The warm liquid then passes through the expansion valve, a narrow opening that throttles the flow. The pressure drops sharply as the liquid squeezes through. A small part of the liquid flashes into vapour, and that evaporation cools the rest of the mixture a great deal.

The refrigerant leaves the valve cold and at low pressure, part liquid and part vapour. No work goes in or out at this step. The cooling comes from the pressure drop alone.

4. The evaporator

The cold mixture enters the evaporator, the coil inside the fridge cabinet. The food and air inside the fridge are warmer than the refrigerant, so heat flows into the refrigerant. That heat is QC, the useful cooling. Absorbing it boils the rest of the liquid into vapour.

The refrigerant leaves the evaporator as a cool, low pressure vapour and flows back to the compressor, where the loop starts again.

Two points about this cycle matter for exams. First, the refrigerant changes phase twice per loop. It condenses in the condenser and evaporates in the evaporator, and those phase changes are what let it carry large amounts of heat with a small mass of fluid.

Second, the real vapour-compression cycle is irreversible. Friction in the compressor, heat leaking through imperfect insulation, and the finite temperature gaps needed for heat to flow at all mean a real machine always falls short of the ideal. The reversed Carnot cycle, a fully reversible cycle running the same way, is the benchmark that real cycles are measured against. It is not a model of what happens inside a real fridge.

Heat Pump and Refrigerator Coefficient of Performance

The coefficient of performance of a refrigerator tells you how much cooling you get for the work you pay for. It is the useful effect divided by the cost. For a refrigerator the useful effect is the heat removed from the cold reservoir, QC, and the cost is the work input, W. So the refrigerator COP formula is COPref = QC / W.

Students often trip over one thing here. COP is not an efficiency, and it is not capped at 1. An efficiency compares work output with heat input, and the second law caps it below 1. A COP compares heat moved with work input, and moving heat is not the same as creating energy.

The machine creates none of the heat it delivers. It only carries heat that already exists from one place to another, and work is only the fee for carrying it. So a COP above 1 is normal, and a COP below 1 would mean a badly designed machine.

A typical domestic fridge runs at a COP between 2 and 4. It moves two to four joules of heat out of the cabinet for every joule of electrical work it consumes.

A quick check makes the definition stick. Suppose a small refrigerator removes 500 J of heat from its interior and the compressor consumes 200 J of work to do it. Then COPref = 500 / 200 = 2.5.

The number has no units, because joules divide by joules. Exam papers love this kind of question because it tests whether you know which heat goes on top. For a refrigerator, the heat on top is always QC, the heat taken from the cold side.

COP also depends on the temperatures involved. The wider the gap between the cold inside and the warm outside, the harder the machine has to push heat uphill, and the lower the COP.

A fridge in a hot kitchen works harder than the same fridge in a cool pantry. A freezer, which holds a much colder interior, runs at a lower COP than a fridge in the same room. The Carnot formulas later in this article make that dependence exact.

Coefficient of Performance of a Heat Pump

A heat pump is the same machine judged by its other end. The owner of a heat pump does not care about the cold side at all. The useful effect is the heat delivered to the warm room, QH, and the cost is still the work input, W. So the heat pump COP formula is COPhp = QH / W.

Now compare the two formulas. They share the same work input and the same cycle, so they must be linked, and the link comes straight from the energy balance QH = QC + W. Divide both sides by W and the result drops out: COPhp = QH / W = (QC + W) / W = QC / W + 1 = COPref + 1. So the heat pump COP is always exactly one greater than the refrigerator COP for the same machine running the same cycle.

If a device scores 3.0 as a refrigerator, it scores 4.0 as a heat pump.

That extra one has a plain meaning. A heat pump delivers two kinds of heat to the room. It delivers the heat it pulled from outside, QC, and it also delivers the work it consumed, which ends up as heat too. A refrigerator throws that second part away into the kitchen as waste. A heat pump counts it as useful output.

Nothing is free here. The work still has to be paid for. But when the goal is heating, every joule of work eventually warms the room, so the COP of a heat pump is always above 1, and a typical air source heat pump runs at a COP between 2 and 4 in mild weather.

This is why heat pumps attract so much attention as a heating technology. An electric heater turns one joule of electricity into one joule of heat, a COP of 1. A heat pump with a COP of 3 delivers three joules of heat for the same joule of electricity, because two of those joules were pulled from the outdoor air rather than made from scratch. The advantage shrinks on very cold days, when the outdoor air holds less heat to pull and the temperature gap widens, but the principle holds all year round.

The Carnot Limit: The Best COP Possible

Every real machine wastes some of its work on friction, turbulence and heat leaking the wrong way. So what is the best COP any refrigerator or heat pump could ever reach?

The answer comes from the Carnot cycle run in reverse. The Carnot cycle is fully reversible, with two isothermal steps and two adiabatic steps, and no real cycle can beat it. Its COP sets the ceiling for every machine working between the same two temperatures.

For a refrigerator working between a cold reservoir at temperature TC and a hot reservoir at temperature TH, the maximum COP is COPref,Carnot = TC / (TH − TC). For the same machine used as a heat pump, the maximum is COPhp,Carnot = TH / (TH − TC). Both formulas need temperatures in kelvin, not Celsius. That detail decides marks in exams, and it is covered again in the mistakes section below.

Look at what the formulas say about the temperature gap. Both COPs have the gap TH − TC in the denominator. When the gap shrinks, the denominator shrinks and the heat pump and refrigerator coefficient of performance both rise, for the refrigerator and for the heat pump alike.

A fridge cooling a room that is only slightly warmer than its interior has an easy job and a high Carnot COP. A freezer in a hot kitchen has a hard job and a low one. The same pattern shows up in real machines, which is one reason heat pumps perform best in mild climates, where indoor and outdoor temperatures sit close together.

The two Carnot formulas also obey the same plus one relation as the ordinary COPs. Subtract them and the result is COPhp,Carnot − COPref,Carnot = (TH − TC) / (TH − TC) = 1. That is a handy cross check in an exam. If your two Carnot COPs do not differ by exactly 1, one of them is wrong.

Keep in mind what this ceiling means. It is the best possible COP between those two temperatures, not a prediction of what a real machine achieves. A real fridge reaches perhaps a third of its Carnot COP, and the worked example below shows exactly how wide that gap is.

The reasons are ordinary and physical: heat needs a temperature difference to flow at all, so a real condenser must run hotter than the room and a real evaporator colder than the food, which widens the effective gap; the compressor loses work to friction; and the expansion valve throws away energy that an ideal cycle would recover. The Carnot limit stays useful because it tells you which direction to push.

Narrow the temperature gap, and every COP improves.

Worked Example 1: A Refrigerator’s COP

A refrigerator removes 12 kJ of heat from its interior and rejects 16 kJ of heat to the kitchen in the same cycle. Find the work input, the refrigerator COP, and the COP the same machine would score as a heat pump.

Step 1: Write down what you know. QC = 12 kJ, the heat removed from the cold interior. QH = 16 kJ, the heat rejected to the hot kitchen. The work input W is unknown.

Step 2: Find the work from the energy balance. QH = QC + W, so W = QH − QC = 16 kJ − 12 kJ = 4 kJ. The compressor consumes 4 kJ of work per cycle.

Notice the sanity check built into this step. The heat rejected must exceed the heat removed, because the work adds to it. If your numbers ever give QH smaller than QC, you have swapped the two heats.

Step 3: Find the refrigerator COP. COPref = QC / W = 12 kJ / 4 kJ = 3.0. The kilojoules cancel and the COP has no units. A value of 3.0 sits in the normal range for a domestic fridge, which is a good sign the numbers are sensible.

Step 4: Treat the same cycle as a heat pump. COPhp = QH / W = 16 kJ / 4 kJ = 4.0. The same machine, judged by the heat it delivers instead of the heat it removes, scores 4.0.

Step 5: Check with the plus one rule. COPref + 1 = 3.0 + 1 = 4.0, which matches the heat pump COP just calculated. The two methods agree, so the answer is consistent. One cycle, two scores, and the difference is always exactly one.

Worked Example 2: A Carnot Refrigerator Between Two Temperatures

A Carnot refrigerator works between a cold reservoir at 5 °C and a hot reservoir at 35 °C. Find the maximum possible refrigerator COP and the corresponding heat pump COP, then compare the result with a real fridge.

Step 1: Convert both temperatures to kelvin. The Carnot formulas need absolute temperature. Add 273 to each Celsius value. TC = 5 + 273 = 278 K. TH = 35 + 273 = 308 K. The gap between them is TH − TC = 308 K − 278 K = 30 K.

Note that a temperature difference in kelvin is the same number as the difference in Celsius, so the gap could have been read straight off the Celsius values, but the individual temperatures in the formulas must be kelvin.

Step 2: Find the maximum refrigerator COP. COPref,Carnot = TC / (TH − TC) = 278 / 30 = 9.27. No real refrigerator working between 5 °C and 35 °C can beat 9.27.

Step 3: Find the corresponding heat pump COP. COPhp,Carnot = TH / (TH − TC) = 308 / 30 = 10.27. Again, check with the plus one rule: 9.27 + 1 = 10.27. The two Carnot COPs differ by exactly one, as they must.

Step 4: Compare with a real fridge. A typical domestic refrigerator runs at a COP of about 3, far below the Carnot ceiling of 9.27. The gap is not a mistake in the theory. Real machines lose out to friction in the compressor, to the temperature differences needed to make heat flow at a useful rate, and to the energy thrown away in the expansion valve.

The Carnot cycle assumes every step is reversible and infinitely slow, which no real machine can afford. Still, the comparison is useful. It shows how much headroom better engineering has to chase, and it shows why narrowing the temperature gap is the most powerful way to raise any COP.

Common Mistakes

A few errors show up again and again on this topic, in homework and in exams. They are all easy to avoid once you have seen them spelled out.

  • Confusing COP with efficiency and claiming it cannot exceed 1. An efficiency compares work out with heat in and is capped below 1 by the second law. A COP compares heat moved with work in, and heat moved can exceed the work paid, so a COP of 3 or 4 is perfectly normal. If an exam asks for a refrigerator COP and your answer comes out below 1, check your numbers before trusting it.
  • Swapping QC and QH in the COP formulas, so the refrigerator and heat pump answers come out backwards. QC is the heat taken from the cold side and belongs on top for a refrigerator. QH is the heat delivered to the hot side and belongs on top for a heat pump. The energy balance QH = QC + W tells you that QH is always the larger of the two, so if your QC exceeds your QH, you have them the wrong way round.
  • Using Celsius instead of kelvin in the Carnot COP formulas. The formulas come from ratios of absolute temperatures, so they need kelvin. Using 5 °C and 35 °C directly gives 5 / 30, about 0.17, a nonsense answer for a refrigerator COP. Always add 273 before touching a Carnot formula.
  • Forgetting that an open fridge door warms a room rather than cooling it. With the door open, the fridge still removes heat QC from its interior and dumps QH = QC + W into the room. The room gains more heat than the fridge removes, because the work adds to the total. The kitchen ends up warmer, and the electricity meter spins faster for nothing.
  • Treating the reversed Carnot cycle as the cycle real fridges actually use. Real fridges use the vapour-compression cycle, with a compressor, a condenser, an expansion valve and an evaporator. The reversed Carnot cycle is a reversible ideal. It sets the maximum COP and nothing else. Mixing the two up leads to wrong diagrams and wrong explanations of how the machine works.

Conclusion

The heat pump and refrigerator coefficient of performance is one ratio with two faces. A refrigerator is judged by the heat it removes, COPref = QC / W. A heat pump is judged by the heat it delivers, COPhp = QH / W. Both rest on the energy balance QH = QC + W, and that balance forces the neat link COPhp = COPref + 1.

The vapour-compression cycle does the actual work, carrying heat uphill in four steps, while the reversed Carnot cycle sets the ceiling no real machine can pass: COPref,Carnot = TC / (TH − TC) and COPhp,Carnot = TH / (TH − TC), with temperatures in kelvin.

Keep those six formulas together and the whole topic falls into place. Given any two of QC, QH and W, the energy balance finds the third, and the COP follows in one division. Given two reservoir temperatures, the Carnot formulas give the best COP possible, and any real machine will sit well below it. Next time a fridge hums in the corner of a kitchen, the numbers behind the hum are these: work in, heat moved uphill, and a COP that says how well the machine spent its work.

Frequently Asked Questions

What is the coefficient of performance of a refrigerator, and how is COP_ref calculated?

The coefficient of performance of a refrigerator, COP_ref, is the ratio of the heat removed from the cold reservoir to the work input, and it is calculated as COP_ref = Q_C / W. Q_C is the heat taken from inside the fridge and W is the work the compressor consumes. A typical domestic fridge has a COP between 2 and 4, so it moves two to four joules of heat for every joule of work.

How is the heat pump COP formula different from the refrigerator COP formula?

The heat pump COP formula uses the heat delivered to the hot side on top, COP_hp = Q_H / W, while the refrigerator COP formula uses the heat removed from the cold side, COP_ref = Q_C / W. Both formulas share the same work input W and judge the same machine running the same cycle. The only difference is which end counts as the useful effect, so a heat pump owner wants the heat delivered to the warm room.

Why is the heat pump COP always exactly 1 greater than the refrigerator COP?

The heat pump COP is exactly 1 greater than the refrigerator COP because of the energy balance Q_H = Q_C + W. Dividing both sides by the work input W gives COP_hp = Q_H / W = Q_C / W + 1, which is COP_ref + 1. A heat pump delivers the heat it pulled from outside plus the work it consumed, which also ends up as heat. A refrigerator throws that second part away as waste.

What is the maximum COP of a Carnot refrigerator between two given temperatures?

The maximum COP of a Carnot refrigerator between two temperatures is COP_ref,Carnot = T_C / (T_H – T_C), where T_C is the cold reservoir temperature and T_H is the hot reservoir temperature, both in kelvin. No real refrigerator working between those temperatures can beat this value. For example, a Carnot refrigerator between 5 °C (278 K) and 35 °C (308 K) has a maximum COP of 278 / 30 = 9.27, far above a real fridge at about 3.

How does the vapour compression cooling cycle in a refrigerator actually work?

The vapour compression cooling cycle moves heat uphill in four repeating stages. First the compressor squeezes low pressure vapour, raising its pressure and temperature. Next the condenser lets the hot vapour release heat Q_H to the surroundings as it condenses into liquid. Then the expansion valve drops the pressure sharply, cooling the refrigerant. Finally the evaporator absorbs heat Q_C from inside the fridge as the liquid vaporises, and the vapour returns to the compressor.

Can the COP of a heat pump or refrigerator be greater than 1?

Yes, the COP of a heat pump or refrigerator can be greater than 1, and a typical domestic fridge runs at a COP between 2 and 4. COP is not an efficiency, so the second law does not cap it at 1. An efficiency compares work output with heat input, but a COP compares heat moved with work input. The machine creates none of the heat it delivers. It only moves heat that already exists from one place to another.